NM01IQI1B
Choose Quantity
ASTM E747-97 Set B Wire Type Penetrameter
2 in Stainless Steel / Ferrous Wire Image Quality Indicator (IQI), Set B, for Industrial Radiographic Testing
SKU: IQI1B
Overview
The IQI1B is an ASTM E747-97 Set B wire-type penetrameter, also known as a wire Image Quality Indicator (IQI), designed for verifying radiographic image quality and sensitivity during industrial X-ray and gamma-ray inspection.
This configuration uses stainless steel / ferrous (SS/FE) wires and is intended for radiographic inspection of compatible ferrous materials. The precision wire elements provide a known dimensional reference that allows radiographers to determine whether the required level of image quality has been achieved on the completed radiograph.
During exposure, the penetrameter is positioned according to the applicable radiographic procedure. After processing or image acquisition, the smallest required wire that remains visible is used as an indication of achieved radiographic sensitivity.
The 2 in configuration and ASTM Set B designation make SKU IQI1B suitable for professional weld inspection, fabrication QA/QC, pipeline radiography, pressure-vessel examination, casting inspection, and other industrial RT applications.
What's Included
| Item | Details |
|---|---|
| Wire Type Penetrameter / IQI | ASTM E747-97 Set B |
| IQI Type | Wire type |
| Set | B |
| Material | Stainless Steel / Ferrous (SS/FE) |
| Nominal Length | 2 in |
| Primary Function | Verification of radiographic image quality and sensitivity |
| Inspection Method | Radiographic Testing / RT |
| Applicable Standard | ASTM E747-97 |
| SKU | IQI1B |
Note: Radiographic film, digital detector, cassette, lead screens, identification markers, source equipment, and other radiography accessories are not included unless specified separately.
Box Dimensions & Shipping Weight (Estimated)
| Parameter | Imperial |
|---|---|
| Length | 4.0 in |
| Width | 3.0 in |
| Height | 1.0 in |
| Dimensions (L × W × H) | 4.0 × 3.0 × 1.0 in |
| Weight | 0.25 lb |
Actual shipping dimensions and weight may vary depending on protective case, labeling, and packaging configuration.
Key Specifications
| Parameter | Details |
|---|---|
| Product Type | Wire Image Quality Indicator / Penetrameter |
| Model / Set | ASTM Set B |
| Standard | ASTM E747-97 |
| Material Group | Stainless Steel / Ferrous |
| Material Designation | SS/FE |
| IQI Configuration | Multiple precision wires |
| Nominal Length | 2 in |
| Primary Use | Radiographic sensitivity verification |
| Radiation Methods | Industrial X-ray and gamma-ray radiography |
| Inspection Method | Radiographic Testing / RT |
| Typical Inspection Environment | Field, fabrication, laboratory, and QA/QC |
| SKU | IQI1B |
Wire-Type IQI Configuration
Wire-type IQIs use a series of precision wires with progressively changing diameters.
The configuration allows the radiographer to:
Establish a known image-quality reference
Verify radiographic sensitivity
Determine the smallest discernible wire
Compare image quality against procedural requirements
Confirm that exposure conditions provide adequate detail
Document radiographic technique performance
The exact required visible wire is determined by the component thickness, governing specification, inspection technique, and applicable acceptance procedure.
How the Penetrameter Works
During radiographic inspection:
The correct IQI set and material group are selected.
The penetrameter is positioned on or adjacent to the component according to the applicable procedure.
The component and IQI are exposed using the selected X-ray or gamma-ray technique.
The resulting radiograph or digital image is evaluated.
Individual wires are examined for visibility.
The smallest required visible wire is used to verify that the required image-quality level has been achieved.
The IQI does not determine whether a component itself is acceptable or rejectable. It verifies that the radiographic technique has sufficient image quality to perform the required evaluation.
Performance Features
ASTM E747 Wire-Type Design
Designed around the wire-type IQI method specified for industrial radiographic image-quality evaluation.
Set B Configuration
Provides the wire-size range associated with ASTM Set B applications.
SS/FE Material Construction
Suitable for applicable stainless steel and ferrous-material radiography where the selected IQI material matches the inspection requirements.
Precision Wire Elements
Uses controlled wire dimensions to provide a repeatable radiographic sensitivity reference.
2 in Configuration
Compact size supports positioning on welds, plates, piping, vessels, and other industrial components.
Reusable Inspection Accessory
Can be used repeatedly when wires, identification, and protective construction remain undamaged and within applicable requirements.
Advantages of Wire-Type IQIs
Wire-type image quality indicators provide several practical advantages for industrial radiography:
Easy visual determination of image quality
Multiple sensitivity references in one IQI
Suitable for film and compatible digital radiography
Compact configuration
Useful for weld and component inspection
Supports standardized radiographic procedures
Provides objective image-quality verification
Suitable for field and laboratory use
Reusable when properly protected and maintained
User-Friendly Design
Compact 2 in configuration
Multiple precision wires in one indicator
Easy to position near the inspection area
Suitable for conventional film radiography
Compatible with applicable digital radiography workflows
Clear Set B identification supports proper selection
Portable for field radiography kits
Suitable for repeated QA/QC inspections
Requires no power or electronic interface
Built for Industrial Radiography
Designed for professional NDT use
Suitable for fabrication and welding inspection
Practical for pipeline radiography
Supports pressure-vessel examination
Useful for structural and manufacturing QA/QC
Suitable for X-ray and gamma-ray applications
Can be integrated into documented radiographic procedures
Supports permanent inspection records
Intended for use by qualified radiographic personnel
Applicable Standard
The IQI is identified for use with:
ASTM E747-97 — Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology
The applicable revision required by the customer's inspection procedure should always be verified before use.
Other codes and specifications may reference ASTM wire-type IQIs as part of their radiographic inspection requirements.
Material Compatibility
The SS/FE configuration is intended for use with suitable ferrous materials, subject to the governing inspection procedure.
Typical applications may involve:
Carbon steel
Stainless steel
Low-alloy steel
Ferrous weldments
Ferrous castings
Steel forgings
Steel plate
Steel piping
Pressure components
The IQI material group should be selected according to the material being inspected and the requirements of the applicable code or procedure.
Ideal Applications
Weld radiography
Pipeline weld inspection
Pressure-vessel radiography
Structural steel inspection
Storage-tank weld inspection
Casting radiography
Forging inspection
Boiler component examination
Fabrication QA/QC
Manufacturing quality control
Aerospace component radiography where applicable
Power-generation component inspection
X-ray radiographic testing
Gamma-ray radiographic testing
Radiographic procedure qualification
Image-quality verification
Typical Inspection Workflow
The IQI can be incorporated into radiographic workflows involving:
Source selection
Source-to-object distance setup
Film or detector placement
IQI positioning
Exposure calculation
Radiographic exposure
Film processing or digital image acquisition
Density or image-quality evaluation
Wire visibility assessment
Indication interpretation
Inspection documentation
The IQI should be positioned and interpreted according to the governing inspection procedure.
Placement Considerations
For reliable image-quality verification:
Select the correct IQI material and Set designation
Position the IQI according to the applicable code
Place it as close as practical to the area of interest
Use source-side placement when required
Follow procedural requirements if film-side placement is necessary
Ensure wire orientation meets the applicable inspection requirements
Avoid positioning the IQI where component geometry could interfere with interpretation
Clearly identify the IQI and its location on the radiograph
Incorrect placement can invalidate image-quality verification.
Inspection and Interpretation
When evaluating the completed radiograph:
Confirm the IQI image is clearly visible
Identify individual wire indications
Determine the smallest wire that can be reliably resolved
Compare the result with the required sensitivity
Confirm applicable density or digital image-quality requirements
Document the IQI used
Record any required wire designation or sensitivity result
Retain the radiograph or digital image according to the inspection procedure
Wire visibility should be evaluated by qualified personnel under appropriate viewing conditions.
Care and Handling
Handle the IQI carefully to prevent wire deformation
Avoid bending or crushing the penetrameter
Keep the wire elements clean
Do not grind, file, or modify individual wires
Protect identification markings from damage
Inspect the IQI before each use
Remove contamination carefully when required
Store flat in a protective case
Keep separate from heavy or sharp tools
Replace the IQI if wires become damaged, corroded, missing, or distorted
Damage to an individual wire may affect the validity of radiographic sensitivity evaluation.
Safety Considerations
The IQI itself does not produce radiation; however, it is intended for use during industrial radiographic testing.
When using the product:
Radiographic exposures must be performed by trained and authorized personnel
Establish appropriate radiation boundaries
Use approved radiation survey instrumentation
Wear required personal dosimetry
Control access to the exposure area
Follow source-handling procedures
Verify the area is safe before retrieving the IQI
Follow all applicable radiation-protection requirements and site procedures
About Wire Image Quality Indicators
Wire Image Quality Indicators are precision radiographic reference devices used to demonstrate the image quality achieved during industrial radiography. By providing multiple known wire diameters within a single indicator, they allow qualified inspectors to verify that an X-ray or gamma-ray image has sufficient sensitivity for the required examination.